Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
ABC., imagem cardiovasc ; 35(3): eabc280, 2022. tab, ilus
Article in Portuguese | LILACS | ID: biblio-1411955

ABSTRACT

Cor triatriatum é um anomalia cardíaca congênita rara frequentemente diagnosticada na primeira infância. Este estudo de caso apresenta um adulto com um achado acidental de cor triatriatum sinistrum. Com base na apresentação clínica, o paciente foi tratado de forma conservadora. São apresentados achados de imagens ecocardiográficas de cor triatriatum sinistrum deste paciente juntamente de revisão narrativa da literatura sobre essa doença.(AU)


Cor triatriatum is a rare congenital heart anomaly often diagnosed in early childhood. This case study features an adult with an incidental finding of cor triatriatum sinistrum. Based on the clinical presentation, the patient was treated conservatively. Cor triatriatum sinistrum echocardiographic image findings of this patient are presented along with a narrative review of the literature about this disease. (AU)


Subject(s)
Humans , Male , Middle Aged , Cor Triatriatum/complications , Cor Triatriatum/diagnostic imaging , Incidental Findings , Heart Atria/abnormalities , Magnetic Resonance Spectroscopy/methods , Echocardiography, Doppler/methods , Echocardiography, Transesophageal/methods , Echocardiography, Three-Dimensional/methods , Fatty Liver/complications , Heart Septal Defects, Atrial/complications , Kidney/injuries , Myocardial Infarction/genetics
2.
Rev. bras. ecocardiogr. imagem cardiovasc ; 25(3): 193-194, jul.-set. 2012. ilus
Article in Portuguese | LILACS | ID: lil-641352
6.
Arq. bras. cardiol ; 85(6): 397-402, dez. 2005. graf
Article in Portuguese | LILACS | ID: lil-419798

ABSTRACT

OBJETIVO: Estudar um grupo de pacientes com lesão significativa em apenas uma artéria coronária e demonstrar se a ecocardiografia de estresse com dobutamina (EED) tem boa sensibilidade e especificidade na avaliação de viabilidade miocárdica nesse grupo de pacientes. MÉTODOS: Foram estudados 20 pacientes submetidos a angioplastia coronariana transluminal percutânea (ATC). Esse grupo foi avaliado 2 a 7 (3,65 ± 1,69) dias antes do procedimento, e 2 a 5 (4 ± 0,80) dias depois, realizando-se EED. Para a determinação de viabilidade miocárdica foi utilizado ecocardiograma bidimensional três meses após o procedimento. Doze pacientes foram submetidos a ATC de artéria descendente anterior (DA), 7 de artéria coronária direita (CD) e 1 de circunflexa (CX). Apenas um procedimento (CD) não obteve pleno êxito. RESULTADOS: Dos 340 segmentos estudados, 99 (29,18 por cento) demonstraram alterações contráteis, sendo 63 hipocinéticos (63,4 por cento), 28 acinéticos (28,28 por cento) e 8 discinéticos (8,08 por cento). Quanto aos segmentos envolvidos, obtivemos sensibilidade de 92,59 por cento, especificidade de 84,45 por cento, acurácia de 88,88 por cento para o exame EED. O único caso de ATC de CX demonstrou sensibilidade de 100 por cento; para DA, sensibilidade de 88,58 por cento, especificidade de 95 por cento e acurácia de 90,91 por cento. Para segmentos da CD, sensibilidade de 91,30 por cento, especificidade de 83,33 por cento e acurácia de 88,71 por cento. Todos os segmentos discinéticos eram inviáveis. Dos 63 hipocinéticos, a EED previu recuperação em 91,48 por cento. CONCLUSÃO: A EED é útil na avaliação de viabilidade miocárdica em pacientes com lesão significativa de apenas uma artéria.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Cardiotonic Agents , Coronary Circulation/physiology , Dobutamine , Echocardiography, Stress/standards , Coronary Stenosis , Angioplasty, Balloon, Coronary , Coronary Circulation/drug effects , Myocardial Contraction/physiology , Coronary Stenosis/physiopathology , Coronary Stenosis/therapy , Sensitivity and Specificity , Statistics, Nonparametric , Tissue Survival/physiology , Treatment Outcome
7.
Arq. bras. cardiol ; 83(5): 414-423, nov. 2004. ilus, tab
Article in English, Portuguese | LILACS | ID: lil-387190

ABSTRACT

OBJETIVO: Comparar a ecocardiografia de contraste miocárdico (ECM) usando PESDA e adenosina em bolus (ADN) com a cintilografia miocárdica com radioisótopos (CM) em pacientes (pts) submetidos a investigação e alta probabilidade de doença arterial coronariana. MÉTODOS: Foram estudados 125 pts, 58,4 ± 10,6 anos, 85 homens, com ECM e CM, realizados com intervalo máximo de 4 semanas. ECM foi realizada com PESDA em infusão contínua em repouso e após ADN. As paredes do VE foram divididas em 3 territórios relacionados às artérias coronarianas, totalizando 375 territórios. ECM foi normal quando houve aumento da intensidade do contraste após ADN. Diminuição da intensidade do contraste em repouso ou após ADN foi definida como ECM anormal. CM foi realizada usando protocolos clássicos. Comparados por pacientes, foram considerados concordantes quando ambos exames eram normais ou anormais independente de localização. A comparação por território foi considerada concordante quando havia ou não déficit perfusional num mesmo território. A significância da concordância foi feita pelo teste do qui-quadrado. RESULTADOS: Em 106/125 pts ECM e CM foram concordantes (84,8 por cento - p<0,001). Houve concordância em 342/375 territórios (91,2 por cento - p<0,001). Para o território de DA a concordância foi de 87,2 por cento, para CD 93,6 por cento e para CX 92,8 por cento (p<0,001). CONCLUSAO: Existe uma ótima concordância entre ECM e CM nos pts em investigação para doença arterial coronariana, podendo a ECM representar uma alternativa à avaliação da perfusão miocárdica.


Subject(s)
Humans , Male , Female , Contrast Media , Coronary Artery Disease , Coronary Artery Disease , Echocardiography/methods , Adenosine , Albumins , Longitudinal Studies , Prospective Studies
8.
Arq. bras. cardiol ; 78(3): 281-298, Mar. 2002. ilus, tab, graf
Article in English, Portuguese | LILACS | ID: lil-305035

ABSTRACT

OBJECTIVE: To test the feasibility, safety and accuracy of the adenosine protocol in the study of myocardial perfusion with microbubbles contrast echocardiography. METHODS: 81 pts (64 male, 60+11 years) were submitted to contrast echocardiography with PESDA (sonicated solution of albumin 20 percent-1ml, dextrose 5 percent-12ml and deca-fluorobutane gas-8ml) to study the myocardial perfusion at rest and after bolus injection of adenosine (6 to 18mg) and to coronary angiography within 1 month each other. For each patient 3 left ventricle perfusion beds were considered (total of 243 territories). 208 territories were analyzed and 35 territories were excluded. PESDA was continuously infused (1-2ml/min), titrated for best myocardial contrast. Triggered (1:1) second harmonic imaging was used. RESULTS: Coronary angiography showed 70 flow limiting (> 75 percent) lesions and 138 no flow limiting lesions. At rest an obvious myocardium contrast enhancement was seen in at least 1 segment of a territory in all patients. After adenosine injection an unquestionable further increase in myocardial contrast was observed in 136 territories (99 percent) related to no flow limiting lesions, lasting < 10 s, and a myocardial perfusion defect was detected in 68 territories (97 percent) related to flow limiting lesions. It was observed only 4 false results. There were no serious complications. CONCLUSION: Myocardial perfusion study with PESDA and adenosine protocol is a practical, safe and accurate method to analyze the coronary flow reserve


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Adenosine , Coronary Circulation , Coronary Disease , Echocardiography , Vasodilator Agents , Aged, 80 and over , Clinical Protocols , Contrast Media , Coronary Angiography , Coronary Disease , Hemodynamics , Injections, Intravenous , Rest
9.
Arq. bras. cardiol ; 76(1): 15-28, jan. 2001. ilus, tab
Article in Portuguese, English | LILACS | ID: lil-279895

ABSTRACT

OBJECTIVE: To identiy left ventricular geometric patterns in hypertensive patients on echocardiography, and to correlate those patterns with casual blood pressure measurements and with the parameters obtained on a 24-hour ambulatory blood pressure monitoring. METHODS: We studied sixty hypertensive patients, grouped according to the Joint National Committee stages of hypertension.. Using the single- and two-dimensional Doppler Echocardiography, we analyzed the left ventricular mass and the geometric patterns through the correlation of left ventricular mass index and relative wall thickness. On ambulatory blood pressure monitoring we assessed the means and pressure loads in the different geometric patterns detected on echocardiography RESULTS: We identified three left ventricular geometric patterns: 1) concentric hypertrophy, in 25 percent of the patients; 2) concentric remodeling, in 25 percent; and 3) normal geometry, in 50 percent. Casual systolic blood pressure was higher in the group with concentric hypertrophy than in the other groups (p=0.001). Mean systolic pressure in the 24h, daytime and nighttime periods was also higher in patients with concentric hypertrophy, as compared to the other groups (p=0.003, p=0.004 and p=0.007). Daytime systolic load and nighttime diastolic load were higher in patients with concentric hypertrophy ( p=0.004 and p=0.01, respectively). CONCLUSIONS: Left ventricular geometric patterns show significant correlation with casual systolic blood pressure, and with means and pressure loads on ambulatory blood pressure monitoring


Subject(s)
Humans , Adolescent , Adult , Middle Aged , Hypertension , Heart Ventricles , Analysis of Variance , Blood Pressure Monitoring, Ambulatory , Stroke Volume
10.
Rev. bras. ter. intensiva ; 4(2): 42-4, abr.-jun. 1992. ilus
Article in Portuguese | LILACS | ID: lil-200017

ABSTRACT

A utilidade da ecocardiografia transtorácica (ETT) é bastante satisfatória. Todavia, na unidade de terapia intensiva nem sempre é possível realizar uma ETT, geralmente devido ao fato de que o paciente se encontra sob assistência respiratória ao apresentar algum tipo de transtorno respiratório que impossibilita a realizaçäo perfeita do exame. Os autores relatam sua experiência com a ecocardiografia transesofágica (ETE) em uma unidade de terapia intensiva. A ETE é facilmente realizada em pacientes críticos, inclusive naqueles com infarto agudo do miocárdio, sem praticamente qualquer risco. Depois de descreverem o método de sua introduçäo, os autores chamam a atençäo para as principais indicaçöes da ETE em uma unidade de terapia intensiva. Discutem sua utilidade no choque circulatório, embolias sistêmica e pulmonar, infarto agudo do miocárdio, aneurisma dissecante da aorta, endocardite e avaliaçäo pós-operatória dos pacientes.


Subject(s)
Humans , Aortic Aneurysm , Aortic Dissection , Echocardiography, Transesophageal , Embolism , Endocarditis , Myocardial Infarction , Intensive Care Units , Pulmonary Embolism , Shock
SELECTION OF CITATIONS
SEARCH DETAIL